VORTEX 150-200

Submersible pumps in cast-iron for sewage water, 2 poles, from 1.1kW to 1.5kW,
Max head: 11 m,
Max capacity: 550 L/min

Description

Pump in cast-iron with "vortex" impeller. When the impeller turns, it creates a vortex pushing the water through the pump body. As the impeller is positioned in the upper part of the pump body it permits a wide free passage for the solid parts contained into the water. Thanks to its heavy duty construction, the double indipendent mechanical seals and the top quality oil bathed motor the VORTEX 150 and VORTEX 200 can be used to pump sewage water and manure.

In case an electrical problem occurs, the reparation of the pump is extremely easy because the electric connections and the capacitor are positioned under the cover and completely isolated from the motor; so if some water enters into the pump from a cut in the cable the motor will be safe.

Use

The VORTEX 150 and VORTEX 200 are usually installed into block of flats' cellars to drain the rain water or the domestic sewage water but these models are also often used in farms to pump out the manure of the stables, in industrial plants, in sewage water treatment plants, etc. These models cannot be used to pump water containing stones.

Operation conditions

Max liquid temperature: 40 °C (104 °F)

pH: 6-10

Max density < 1100 kg/m³

Max immersion depth: 5m

 

 

Performance curve:

Models Head (m)
2 3 4 5 6 7 8 9 10
Capacity
VORTEX 150 L/min 450 398 350 285 245 175 110 50 0
m3/h 27,0 23,9 21,0 17,1 14,7 10,5 6,6 3,0 0
L/s 7,50 6,63 5,83 4,75 4,08 2,92 1,83 0,83 0
VORTEX 200 L/min 550 520 480 425 370 320 245 180 100
m3/h 33,0 31,2 28,8 25,5 22,2 19,2 14,7 10,8 6,0
L/s 9,17 8,67 8,00 7,08 6,17 5,33 4,08 3,00 1,67

 

 

Technical characteristics:

Models VORTEX 150 VORTEX 200
Outlet 2" - DN 50 horizontal threaded
Solid passage 50mm
Impeller Back open impeller "vortex" type.
Mechanical seal Double indipendent mechanical seal in oil chamber. The lower one in silicum carbide / silicum carbide / NBR, the upper one in ceramic / graphite / NBR. 
Motor Oil bathed. Insulation class: F
Motor protection Automatic reset built-in thermal protection for single-phase models; by a fused remote isolator switch at customer's care (see optional electric board) for three-phase models
Float-switch The single-phase models can be supplied with or without float-switch; the three-phase models are supplied without float-switch
Cable 10 metres cable H07RNF 3G1.5 with plug for single-phase models; 10 metres cable H07RNF 4G1.5 without plug for three-phase models 
Capacitor 30μF - 450V for VORTEX 150 40μF - 450V for VORTEX 200
(only for single-phase models)
IP 68

  

 

Electric characteristics:

Models           Power Nos. poles R.p.m. Voltage Ampere
VORTEX 150 1.5 HP - 1.1kW 2 2850 230V/50Hz/1 8,9 A
400V/50Hz/3 3,5 A
VORTEX 200 2.0 HP - 1.5kW 2 2850 230V/50Hz/1 10,0 A
400V/50Hz/3 5,0 A

 

 

Materials:

Impeller              Cast-iron GG 20                                                              
Pump cover Cast-iron GG 20
Motor case Cast-iron GG 20
Pump body Cast-iron GG 20
Pump support Cast-iron GG 20
Motor shaft Inox AISI 304
Packing set NBR

 

 

Weight and dimensions:

 

Models         Outlet           Dimensions (mm)           Weight
female threaded A B C D E (kg)
VORTEX 150 2" - DN 50 520 220 295 255 550 33
VORTEX 200 2" - DN 50 520 220 295 255 550 34

 

 

 Optionals:

Connections Professional 90° brass connection 2" in three pieces
Standard 90° plastic connection 2" in one piece 
Coupling foot MODEL 1-2": automatic coupling foot with 2" connection 
No-return valve Professional ball check valve threaded 2" in cast-iron
Float-switch 10 or 20 metres cable float-switch to be connected to an electric board in case it is not possible to use the standard float-switch connected to the pump
Electric board Model F5-0.5/3-1 for single-phase pumps or model F6-0.5/10-3 for three-phase pumps. The electric board provides a manual reset thermal protection to protect the motor of the pump and it permits the connection of a float-switch. In the three-phase pumps (that have no protection built-in into the motor and without the possibility to connect a float-switch directly on the pump) the electric board is mandatory.

 

 

VORTEX 150-200 ENG - REV. 2.2 - 10/01/2022

Comex Srl Società Unipersonale, Via delle Industrie, 42 - 31057 Silea (TV) - ITALY
P.I.: 00345210264 - Cap. Soc.: 50.000€ i.v.